Aerial Bunched Cable Current Rating Calculator & size chart

Aerial bunched Cable current rating calculator/ Aerial bundled cable size calculator

AB Cable Calculator

AB Cable Calculator

Aerial Bunched Cable Definition

Aerial bunch cable consists xlpe insulated phase conductor and all three-phase conductors are twisted with each other over messenger wire. Phase conductor of ab cables can be either single-phase or three-phase. In addition to the phase conductor, an extra conductor is available for street lighting. AB cable consists of a messenger conductor beside the phase and lighting conductors that support the weight of the cable and keep the assembly under tension. The Messenger conductor works as a neutral conductor for the distribution system. This assembly strung through the j hook on the pole. they are preferred for the distribution of electricity in domestic commercial and small-scale industries. Through the aerial bunched cable current rating calculator or AB cable size chart, we can calculate the current-carrying capacity of the AB cable/ aerial bunch cable.

Aerial Bunched Cable insulation-

XLPE insulation is a cross-link low-density polyethylene. which is made by Thermo state. The polymeric property of xple makes this insulation flexible and high insulation.

Aerial bunch conductors are a new concept in electrical distribution systems. In the past, bare conductors or PVC cables were used in distribution systems to build lines and distribute electricity. But in today's time, ab cable is more useful in power distribution in LT line. The main reason for this is that the use of AB cable is effective in preventing theft of electricity, easy access to the line in the least space, and the possibility of an electrical accident is very less. The aerial beach is better used in rural areas and hill areas.

Benefits of Aerial Bunched Conductor-

  1. Due to insulation on phase conductors, It is used in the places where electricity theft is most likely, there is no electricity theft due to the insulation of aerial bunch conductors.
  2. As it takes very little place due to that, it can be used in the place where there is a narrow lane or space is very little, it is more appropriate to use an aerial bunch in place of bare wire.
  3. It is used in places where high stability of supply is required.
  4. In hilly areas, where both overhead lines and underground cables are expensive.
  5. In hilly areas where the cost of construction of overhead lines of underground cables becomes very high.
  6. Places where it is compulsory to give temporary connection.
  7. It provides safety against electrical accidents.

Type of ab cable / Aerial bunched cable

There are four types of aerial bunched cable according to the requirement of the different systems.

  1. Insulated messenger conductor AB cable
  2. Messenger conductor AB cable
  3. Insulated messenger conductor with insulated street light AB cable
  4. Bare messenger conductor with insulated street light AB cable

Insulated messenger conductor AB cable

In this type of aerial bunched cable, along with the phase, the messenger conductor is also with xple insulation. The insulation of the messenger increases the life and current carrying capacity of the conductor. But the cost of the cable also increases. So this type of ab cable is less used.

Bare messenger conductor AB cable

In this type of aerial bunch cable, the phase conductors are insulated but the messenger conductor is not insulated. Using a bare messenger conductor saves cable cost. And it is also economical.

Insulated messenger conductor with insulated street light AB cable

In this type of aerial bunched cable, in addition to the phase neutral conductor, there is another cable which is called lighting cable. As we know phase conductor is always insulated. But messenger and street light conductor is also insulated in this type of cable. In the lighting cable distribution system, lighting is provided in the area along with an electric supply to the consumer. This type of cable is used the least in the distribution network.

Bare messenger conductor with insulated street light AB cable

This type of AB cable also has a phase, neutral conductor in addition to another cable called a lighting cable. As we know phase conductor is always insulated. But in this type of cable, the messenger conductor is bare but the street light conductor is insulated. In the lighting cable distribution system, lighting is also provided in the area along with an electric supply to the consumer. This type is used the most.

Aerial Bunched Cable Size chart

Aerial bunch cable is also called ab cable aerial bundled cable in some places. ab cable size chart/ aerial bundle cable size chart can be downloaded from the below download link. Also, a chart of lt ab cable current rating or ab cable current carrying capacity can be found from the chart.

LT ab cable size chart

SI.
No.
Description and Type of CableNumber of Wires PhaseNumber of Wires MessengerThickness of XLPE Insulation in MM (Phase)Thickness of XLPE Insulationin MM (Messenger)AC Current
Rating Amps
 With insulated messenger conductor     
11 C x 16 mm'+ 25 mm'(insulated)771.201.2072
23 C x 16 mm'+ 25 mm'(insulated)771.201.2064
31 C x 25 mm'+ 25 mm'(insulated)771.201.2099
43 C x 25 mm' + 25 mm'(insulated)771.201.2084
51 C x 35 mm'+ 25 mm' (insulated)771.201.20120
63 C x 35 mm'+ 25 mm'(insulated)771.201.20105
71 C x 35 mm'+ 35 mm' (insulated)771.201.20120
83 C x 35 mm'+ 35 mm'(insulated)771.201.20105
91 C x 50 mm'+ 35 mm'(insulated)771.501.20150
103 C x 50 mm'+ 35 mm'(insulated)771.501.20130
113 C x 70 mm'+ 50 mm'(insulated)771.501.50155
123 C x 70 mm'+ 70 mm'(insulated)771.501.50155
133 C x 95 mm'+ 70 mm'(insulated)1971.501.50190
143 C x 120 mm'+ 70 mm' (insulated)1971.601.50220
153 C x 150 mm' + 70 mm'(insulated)1971.801.50250
       
 With bare messenger conductor     
11 C x 16 mm'+ 25 mm'(bare)771.20N.A72
23 C x 16 mm'+ 25 mm'(bare)771.20 N.A64
31 C x 25 mm'+ 25 mm'(bare)771.20 N.A99
43 C x 25 mm'+ 25 mm'(bare)771.20 N.A84
51 C x 35 mm'+ 25 mm'{bare)771.20 N.A120

6
3 C x 35 mm'+ 25 mm'(bare)771.20 N.A105
71 C x 35 mm'+ 35 mm'(bare)771.20 N.A120
83 C x 35 mm'+ 35 mm'{bare)771.20 N.A105
91 C x 50 mm'+ 35 mm'(bare)771.50 N.A150
103 C x 50 mm'+ 35 mm'(bare)771.50 N.A130
113 C x 70 mm'+ 50 mm'(bare)771.50 N.A155
123 C x 70 mm'+ 70 mm' (bare)771.50 N.A155
133 C x 95 mm'+ 70 mm'(bare)1971.50 N.A190
143 C x 120 mm'+ 70 mm' (bare)1971.60 N.A220
153 C x 150 mm'+ 70 mm'{bare)1971.80 N.A250
LT ab cable size chart

Related Articles-

3-phase-motor-cable-size-calculator

acsr-conductor-size-chart